CONTINUOUS RESPIRATION WITH ADAPTIVE FLOW-THROUGH SYSTEM
WebCRAFTS
LOCAL OR AUTONOMOUS CLOUD CONTROL
Operate CRAFTS directly, through a standalone ESP32, or with a gateway.
Measurements are never stored on the WebCRAFTS VM. This tab keeps every interval-120 row received during the current session in memory; the plot shows the latest 10. Rows are saved only when you explicitly export or start TXT saving.
STEP 1
Instrument connection
Disconnected
This browser saves an authenticated desired profile through DigiFruit. The selected standalone ESP32 or gateway polls and applies it without keeping this tab open.
CRAFTS continues adaptive flow and an armed drain schedule if the browser disconnects. On an authorized reconnection, WebCRAFTS synchronizes the current profiles and re-arms a nonzero drain schedule.
STEP 2
DigiFruit cloud authentication
Not connected
Required for standalone Wi-Fi and gateway control. The secret remains only in this tab’s memory.
STEP 3
Flow control
Waiting for device
Adaptive mode uses the CO₂ band, limits, step, and startup flow.
Edit any control, calculation, or drain field, then use the single update button below. First use defaults to autonomous run at 10 L/h; the ESP32 keeps the last explicit revision and operates through Internet or browser interruptions.
STEP 4
Calculations, drain schedule, and local destination
No cloud revision checked
Connect the DigiFruit key to compare the saved revision with the revision reported by the ESP32.
No destination selected · saving stopped
Choosing a destination does not start recording. Browsers expose the folder and filename, not the complete native path.
STEP 5
Current session results
Ready for CRAFTS data. Session rows stay in memory only until this tab is closed or reloaded, unless you explicitly export or start TXT saving.
ΔCO₂—
Steady respiration—
Dynamic respiration—
Dynamic ethylene—
Correction—
Residence / 95%—
Storage slopes CO₂ / C₂H₄—
SNR / R²—
QC—
Swipe sideways to inspect every measurement column.
Time
CO₂ in (ppm)
CO₂ out (ppm)
Chamber temp (°C)
Chamber RH (%)
Outside CO₂ (ppm)
Outside temp (°C)
Outside RH (%)
Flow set (L/h)
Flow measured (mL/min)
Flow measured (L/h)
C₂H₄ raw
C₂H₄ (ppm)
Both valves
ΔCO₂ (ppm)
Steady respiration
Dynamic respiration
Resp. correction (%)
Steady ethylene
Dynamic ethylene
CO₂ slope
C₂H₄ slope
Residence / 95% (h)
CO₂ / C₂H₄ SNR
R²
Calculation revision
Cloud revision status
QC
No session readings yet.
STEP 6
Realtime plots and diagnostics
Waiting for data
CO₂ in—
CO₂ out—
Temperature—
Flow set—
Flow measured—
Ethylene—
Both valves—
Device diagnostics
Wiring prerequisite: never connect ESP32 GND to a 24 V negative. Pump black/blue return directly to the pump adapter negative; JZ-MOS GND remains open and unconnected. Both 24 V valve coils are parallel on the same VOUT+/VOUT- output and operate together.